New energy vehicle DC power interface surge protection scheme

Shanghai Leimao EMC small brother often received customers: "Our new energy vehicle DC24V power port surge test, DC/DC(or LDO) burned, but I put a high-power TVS in front, why will it break, please help analyze what is the reason?" A suitable protective device is recommended." This kind of problem often plagues customers.
2. Has placed high power TVS why DC/DC (LDO) or will burn out

General DC power supply inlet is first protected and then filtered, engineers will use in the power supply inlet scheme is:
Fuse + anti-reverse diode +TVS+ filter + power supply IC voltage conversion,
A high power TVS(placed according to the product test grade) for surge protection.
EMC brother analyzed the reasons for the above problem as follows:
1) TVS selection VC is too high: although it is a high-power TVS, if its clamping voltage (Vc) is too high, the protection effect of the back-end circuit is relatively poor, and it can not effectively protect DC/DC (LDO). For example, in the circuit commonly used in new energy vehicles, VIN is 24V input voltage, DC/DC module VIN input voltage range is 24-36V, the highest voltage is 36V, TVS uses SMDJ26CA, clamping voltage is 42.1V. This exceeds the DC/DC input voltage range, resulting in burnout. If Table 5LM26CA is used instead, its clamp voltage is 30.3V, which meets the requirements of the back-end DC/DC input range.
2) The surge peak power is large, which exceeds the power bearing capacity of TVS. For example, the above circuit 24V to 4KV, with SMDJ26CA power is too low, only 3KW. If you choose 5LM26CA, you can easily pass 4KV, 5LM26CA power is 5KW.
3)Effects of parasitic inductors and capacitors: In actual circuits, there are parasitic inductors and capacitors, which can cause TVS to respond late, unable to clamp the overvoltage in a timely manner, so that DC/DC (LDO) is damaged。
Unreasonable circuit layout: for example, the cable between TVS and the protected device is too long, or there is no good grounding and power wiring, which may weaken the protection effect of TVS。
3. Shanghai Leimo low clamp voltage (VC) TVS model recommendation
Due to the strong voice of a large number of customer needs, Shanghai Leimo wants to help customers solve the problem, develop a series of low VC new high-power TVS, the main models include:
600W SMB package 26V 6LM26CA,33V, 6LM33CA;
The 3KW includes SMC package 26V,3LM26CA, 33V, 3LM33CA.
The 5KW includes SMC packages of 26V,5LM26CA, 33V, 5LM33CA.
The above models are used for product DC 12V,24V power surge protection.
These voltages are the most demanded by customers, so they are developed first. Other voltages will continue to be developed if there is demand, please continue to pay attention to Shanghai Leimao public number.

In the above table, we compare 3LM26CA and SMDJ26CA of 3KW with the same power. The Vc of 3LM26CA is 28.10V and that of SMDJ26CA is 42.1V, which is more than ten V lower.
Therefore, the choice of Shanghai Lei-Mao with the same power back sweep TVS, can better protect the back-end power IC, to solve the beginning of the article often encountered burned LDO and DC/DC problems.
Leiditech is committed to becoming a leading brand in the supply of electromagnetic compatibility solutions and components, supplying ESD, TVS, TSS, GDT, MOV, MOSFET, Zener, inductors and other products. Lei MAO has an experienced R & D team, can provide personalized customized services according to customer needs, to provide customers with the best quality solutions.
Leave a Reply
- EMC protection design for access control security devices: the four external interfaces that deserve
- From power to antenna: EMC protection design solution for video doorbells
- Solving lightning and ESD hazards in industrial sites: LVDT pressure transmitter protection design
- Micro PLC crashes, resets, and communication packet loss? EMC is the root cause.
- How can humanoid-robot DC power supply systems cope with frequent transient load changes?