Automation control modulePLCSolution to avoid transient surges
简体中文
7days a week from 9:00 am to 9:0pm
+86 18016225001

Shanghai Leiditech上海雷卯电子科技有限公司是专业的静电保护元件厂家,TVS二极管供应商;专业提供防雷防静电方案,电磁兼容EMC免费测试等服务,品质保证,库存充足,型号齐全,值得信赖,如有采购静电保护元件,TVS二极管需求,请联系雷卯,24小时服务热线:021-50828806.

By LEIDITECH | 22 September 2023 | 0 Comments

Automation control modulePLCSolution to avoid transient surges

 

Automation control module
Also known asProgrammable Logic Controller,for shortPLC。thesePLCEnhanced for the harsh environment in which they are installed。Most of the protection is mechanical,To prevent factors such as extreme temperature and humidity。however,electromagnetic interference (EMI)、Electrical fast transient (EFT) Sudden and electrostatic discharge (ESD) Waiting for invisible elements can cause significant voltage transients,Thus damaging unprotected equipment。
Shanghai LeimaoEMCLittle brother said:The use of meticulous layout, appropriate protective circuits, and properly designed isolation can ensure the uninterrupted service life of industrial control systems for many years。
background
sinceSince the invention of the jacquard loom in 1801,PLCAlready exists,Use perforated cards to control the hooks that weave patterns into the fabric。In a long time,Microprocessors enter the labor market,Electronic devices have replaced mechanical control。Small industrial computers use programming languages aimed at simplifying processes and machine control,Completely changed the manufacturing industry。
People quickly realized that,The physics of producing semiconductors may lead toPLCDisappearance in industrial applications。These hazards come from transient current surges caused by various electromagnetic events found in industrial environments。Surge can induce voltage on other cables,Resulting in high voltage on circuits that were never designed to handle them。If the absolute maximum value is exceeded,Damage to semiconductor devices is usually inevitable。
Surge type
EMCBrother, summarize the following types of transient surges that can damage electronic devices。
1)The most commonESDIt is caused by the accumulation of charges on people or devices。During discharge,Will generate extremely high voltage,Damage or destruction of semiconductor components。
2)The damage may be caused by thisCaused by natural phenomenaof,For example, lightning,Or simply wearing insulated shoes,Walk around,Then touch the device,Especially connectors。
3)WhenWhen induction loads such as motors or solenoid valves are disconnected by relays or switches,Will happenEFTburst。Inductors store energy,When the circuit is open,As the inductor releases energy,The current will continue to flow.
V = L(di/dt)
among V In volts,L In units of Henry,i In Amperes,t In seconds。
At the moment the circuit is opened,di/dtCan become very large(Theoretically infinite)。This causes the relay contacts to(Or semiconductor switch)Generate extremely high voltage on the air gap of the。In the case of relays or switch contacts,The voltage can increase enough to ionize air and form an arc。
Arc has negative resistance,Therefore, as the current flows,It will reduce the resistance,Temporarily close the circuit again,Until the arc goes out。This may last for many cycles,Each cycle will result in very large voltage spikes(chart1)。The driving circuit is protected by reverse electromotive force pulses。however,Cables are usually bundled together,These peaks will appear in common mode on all wires。


chart1 Electrical fast transient (EFT) Sudden(Top)repeat,Until the energy in the inductive load dissipates。This may require many cycles and last for several milliseconds。
therefore,Even if the aggressor signal(The initiator of the surge)Protected and located on completely different circuits,EFT Sudden incidents can also occur in other areas(Victimization)Induced voltage on wires,These wires can damage the electronic devices they are connected to。It is common to run carrier cables together with signal wiring,Signal wiring may be exposed to these large spikes。
AndESDExposure varies,These transients occur continuously during normal operation。Whenever the switch、When relays or other control circuits open inductive loads,These types of peaks will appear。
Other sources of surges and destructive currents
1)lightning、User induced ESD、EFT Sudden and Other EMI Source will affect I/O Module poses a threat。however,Other sources,Differential grounding caused by transient and other static sources,Possible damage to interfaces and sensitive measuring electronic components。
What is considered to be“ground”Fully related to measurement。Power supply“Grounding”It returns the local connection。But usually,Due to the resistance in the grounding path,The grounding between devices may be several volts apart,In severe cases, it can reach hundreds of volts or higher。The resistance in grounding can cause this grounding difference,The difference can be static,It can also be dynamic。
In Figure2,Current flowing to the ground(IG)Resistance such as poor soil or grounding connections may be encountered。When current flows through this resistor,A voltage will appear on it,Ideal grounding(0 V)Move to a different location(Based on higher or lower polarity)。

 
chart2. adoptRGfromVThe current flowing to the ground can be at two points(VG1 andVG2)Moving ground potential between,Thus generating a differential voltage between the ground。Under transient conditions,This can reach hundreds of volts or higher
2)Lightning induced current is transient,The grounding differential can be changed under extreme voltage。Although these surges are transient,But due to their high current,They may cause significant damage。When using shielded or neutral wires(Non floating)This is especially true in wiring。

Protection strategy

 
1)IEC61000-4-4 The standards specify the level that equipment must withstand when cables enter the chassis。These standards can test transients of 4000 VConnection for(chart1)。Due toESDandEFTThe overall energy of the pulse group is very low,Therefore, it is best to use transient voltage suppressors(TVS)diodeClamp these pulses to the ground。
These diodes have very low capacitance,It should be as close as possible to the entry point,Connector or pin holder near wire termination。aboutDifferential signal,TVSDiodes should be placed in common mode(Differential pair at both ends)。Adequate connection should be established with the ground plane,To prevent surges during printingcircuit board(PCB)Additional loop current appears inside,Resulting in additional high voltage spikes。



2)To prevent grounding deviation,Isolation is the only answer。Isolation can be achieved in multiple ways。The transformer coupling in the isolated power supply works well,Allow system grounding relative to earth grounding“float”。Transformers are only suitable for low-frequency isolation,Need an AC signal to cross the barrier。For DC control or high-frequency applications(Like communication),Optical isolators are very useful。
But in many applications,Due to increased operating temperature,LEDWill degrade with age,This is something to avoid in highly reliable industrial control systems。The frequency response of the photodiode receiver part of the isolator is usually limited,This limits the maximum operating data rate through the device。
3)perhaps,Semiconductor isolator(asISO7131CC)Provide current isolation through capacitive coupling within the device。They can provide many standards that require more than 2500 VRMS Isolation of,Data rate exceeds 40 to 50 Mbits/s。
The advantage of solid-state devices is that they are not used for optical isolation LED,Over time,Optical isolation will reduce and lose performance。These devices also allow for independent grounding and VCC Connection completely isolated。

conclusion
EMCMy summary is as follows:Industrial gradePLCThe system designers, in addition to the electromagnetic environment,We also need to worry about the mechanical environment of the installation system。lightning、Ground Loop 、ESD and EFT Sudden and various events can generate potential destructive surges。
Designers must consider the standards they are building and the real events that may damage the systems exposed in these environments。The use of careful layout, appropriate protective circuits, and properly designed isolation can ensure the uninterrupted service life of industrial control systems for many years。
ShanghaiLeiditech ElectronicsProfessional provision of electromagnetic compatibility for customersEMCDesign Services for,Provide laboratory testing for free testing,For customersDesign project control cost,andQuick PassEMCProject forAccelerate speed。
Shanghai Leiditech brandLeiditech,Various interface electrostatic lightning protection schemes can be provided,Solve electromagnetic compatibility issues for customers,More protection options,Please search for the mini program on WeChat“EMCElectromagnetic Compatibility Community”Welcome to contactEMC Little brother

Leave a Reply

Your email address will not be published.Required fields are marked. *
Name
E-mail
Content
Verification code
ver_code