leiditech introduced the intelligent gateway communication interface and protection scheme
Under the condition that the environment and system are fully secure, the intelligent gateway should have southbound access and northbound access capabilities, and should also have the ability to open interfaces to obtain or provide other services through management applications. The relevant interface and functional requirements should meet the requirements below the table. 

For the gigabit network discrete lightning protection Shanghai Leiditech recommended the following protection schemes
Advantages of the scheme: for outdoor 1000M network port surge protection,this scheme adopts secondary protection, reliable work, to ensure the integrity of the signal high temperature, meet IEC61000-4-2, level 4, contact discharge 30kV, air discharge 30kV. IEC61000-4-5 10/700μs, 40Ω, 6kV, ± 5 times, this scheme does not lose packets at high temperature.
Recommended model: LC03C1 (3.3V, bidirectional, 1 PF, SOD-323 package)
GDT 3R090-5S (90V bidirectional 1.5PF tripole diameter 5MM package)
Recommended protection solution for integrated lightning protection of gigabit networks

advantages: USB2.0 provides 500Mbps transmission speed, this solution adopts a single device protection, saves space, ensures signal integrity, meets IEC61000-4-2, level 4, contact discharge 20kV, air discharge 20kV If there are overcurrent requirements for Vbus, PTC protection is required.

For SIM card electrostatic Shanghai Leiditech recommended the following protection scheme
advantages: SIM card provides 7.2Mbps transmission speed, this scheme adopts integrated device protection, space saving, to ensure signal integrity, meet IEC61000-4-2, level 4, contact discharge 8kV, air discharge 15kV.

USRV05-4 (5, unidirectional, 0.5PF, SOT-26 package).
For RS485 surge, the following protection scheme is recommended

3R090-5S(90V 1.5PF, 3-pole diameter 5MM)
RS485 surge filter protection Shanghai Leiditech recommends the advantages of the following scheme
Advantages of the scheme:: the use of multi-channel integrated device protection, can ensure signal integrity at the same time, can filter out noise, pass the electrostatic test. Meet: meet IEC61000-4-2, ISO10605-2 level 4, contact discharge 30kV, air discharge 30kV.
Recommended model of Shanghai Leimao: SM712 (7V/12V, bidirectional 45PF, SOT-23 package).
In order to ensure the continuous safe and normal operation of the intelligent gateway, Shanghai Leiditech has designed a complete set of electromagnetic compatibility lightning protection and anti-static protection scheme.
Welcome to our company for guidance and inspection, the address is Room A202, No. 518 Kangshan Road, Pudong New Area, Shanghai, Tel: 021-50828806 50477059.
Leave a Reply
- EMC Protection Device Selection for a Driver-Monitoring Camera
- Encoder Interface ESD Protection
- Personnel detection system interface protection design and component selection
- EMC Protection for Gas Detection Systems: Four Entry Points from Power to Wireless
- PoE power supply methods and EMC protection in the DC power supply system of intelligent logistics r