Lower cost ISO7637-2 5A 5B load dump protection scheme
What is load dump, load dump test scheme and selection of back-end circuit parameters under popular science.
Among the many automotive electronic electromagnetic compatibility tests, the most destructive is the 5A 5B test of ISO7637-2, of course, there are also test items in the ISO16750 standard, but the test waveform is generally the same. Shanghai Leiditech has a special article describing the difference between these two standards, please check the official public account.
What is load dump
The so-called LOAD DUMP is to suddenly cut off the load on the normal operating automobile alternator, which is called single dump. Cutting off the load and cutting off the battery at the same time is called double throwing. Due to the high reliability of the automobile operation process, the load dump test formulated by the ISO organization must have its inherent rationality. The load dump test is a very harsh destructive test.
What is 5A 5B
Car load dump is mainly affected by three factors such as maximum voltage, internal resistance and duration, and how to control the comprehensive influence between these three is the key to our car load dump protection.
Stipulates the test level and measurement method of electrical conduction disturbance along the power line of road vehicles with 12V electrical system and 24V electrical system and its immunity. Among them, the pulse waveform 5A and 5B standard tests are the most destructive test tests and the most difficult test standards to pass.
The 5A standard is an unsuppressed waveform, 5B is a waveform with voltage suppression at the front end of the generator, as shown in the waveform diagram below, in the case of the same internal resistance, the size of the waveform area also shows the size of the energy.
5A 5B energy suppression design
At 5A, the test pulse provides the worst-case scenario. In the case of 12V, the US range is specified as 79 volts to 101 volts, while the internal resistance ranges from 0.5 ohms to 4 ohms, and the surge voltage action time is 40ms to 400ms. If after the load-dump protection has been tested 10 times under the specified pulse, then the protection is proved.
Shanghai Leiditech is an electromagnetic compatibility scheme design and device manufacturer, we have verified a variety of solutions for this test, one by one to provide you with a variety of solutions, engineers can choose by themselves.
The most expensive and largest solution
The above scheme uses the core load-dump protection chip of Meixin, which can meet the load-dump test below 90V, equipped with 2 TO-220 MOSFETs and some peripheral devices, which can meet the test requirements of load-dump 5A 5B, and the price of the scheme is about 20 yuan, which can be considered if it is not bad.
TVS protection scheme with simple structure
Compared with the complex design of Meixin, Shanghai Leiditech Automotive TVS SM8S33CA can meet 90% of customers' load-dump test needs.
The following test data is satisfied
|
|
Supply voltage |
Voltage V |
Internal resistance Ω |
Wavelength ms |
Number of tests |
outcome |
|
SM8S33CA |
27 |
174 |
8 |
350ms |
10 |
PASS |
|
SM8S33CA |
27 |
174 |
4 |
350ms |
10 |
PASS |
|
SM8S33CA |
27 |
174 |
3 |
350ms |
10 |
PASS |
The following test data is also available for 12V systems.
|
|
Supply voltage |
Voltage V |
Internal resistance Ω |
Wavelength ms |
Number of tests |
outcome |
|
SM8S24CA |
87 |
2 |
200ms |
10 |
PASS |
|
|
SM8S24CA |
13.5 |
87 |
2 |
400ms |
10 |
PASS |
|
SM8S24CA |
13.5 |
87 |
1 |
400ms |
10 |
PASS |
|
SM8S24CA |
13.5 |
87 |
0.5 |
400ms |
10 |
PASS |
If only 5B is tested, what solution will be used?
Many cars come with limiters, which can ensure that the output surge does not exceed 5B set value, further reducing the risk of load dumping, for such requirements, we can choose cheap solutions, such as Shanghai Leiditech's SM5S24CA series automotive TVS and 6.6SMDJ24CA.
What are DC-DC design considerations?
Due to the characteristics of TVS itself, the clamping voltage and working voltage will have a range, so 12V system DCDC withstand voltage selection 40V, 24V system DCDC withstand voltage selection 60V, if there is a need for low clamping voltage TVS, Shanghai Leiditech has a special low clamp TVS material, welcome to contact the business.
Leave a Reply
- EMC Protection Device Selection for a Driver-Monitoring Camera
- Encoder Interface ESD Protection
- Personnel detection system interface protection design and component selection
- EMC Protection for Gas Detection Systems: Four Entry Points from Power to Wireless
- PoE power supply methods and EMC protection in the DC power supply system of intelligent logistics r