Leiditech introduced the basic configuration and test standards of intelligent gateways

The basic configuration of the gateway device includes: CPU, memory, storage and other specifications, which should be selected according to the specific functions, and the following parameter values should be referred to:

a) CPU: support ARM, x86, MIPS, RISCV and other architectures, at least 2-core processor;

b) Memory: at least 1G memory space;

c) Storage: At least 8G storage, should support extended memory function.

The safety performance of the gateway equipment should comply with the provisions of GB 4943.1-2011 or IEC 62368-1.

 Note: At this stage, the international certification is in the process of changing the IEC 62368 version, and the design and certification are carried out according to the market demand selection standards. The electromagnetic compatibility of the gateway equipment should meet the requirements of Class A in GB/T 9254-2008. According to the end-use environment of the gateway equipment, select the additional environmental test of electromagnetic compatibility, and the relevant test requirements of electromagnetic compatibility environmental test can be as follows:

1. GB/T 17626.2 electrostatic discharge immunity, electrostatic discharge immunity should meet the requirements of contact discharge level 3 (test voltage 6 kV) and air discharge level 3 (test voltage 8 kV) in GB/T 17626.2-2018.

2. GB/T 17626.3 RF electromagnetic field radiation immunity, RF electromagnetic field radiation immunity should meet the requirements of test level 3 (test field strength 10 V/m) in GB/T 17626.3-2018.

3. GB/T 17626.6 Conducted disturbance immunity of RF field induction, the conducted disturbance immunity of RF field induction should meet the requirements of test level 3 in GB/T 17626.6-2017.

4. GB/T 17626.4 Electrical fast transient burst immunity, the electrical fast transient burst immunity of each port of the smart gateway should meet the requirements of test level 3 (peak voltage of power port and ground port 2KV, peak voltage of signal port and control port 1KV) in GB/T 17626.4-2018.

5. GB/T 17626.5 Surge (shock) immunity, surge (shock) immunity should meet the requirements of the medium, wherein the AC power line line should meet the requirements of class 2, the line ground should meet the requirements of class 3, and other power supply ports and signal lines should meet the requirements of line ground level 2.

6. GB/T 17626.17 DC power input port ripple immunity, DC power input port ripple immunity should meet the requirements of test level 1 (2%) in GB/T17626.17-2005.

Note: The test level requirements in the table are level 3, for the requirements of light industrial environment, if the product is used in commercial environment, it can be adjusted to level 2, and if it is used in harsh industrial environment, it needs to be upgraded to level 4.

Shanghai Leiditech professional has EMC experts, free electromagnetic compatibility solutions, free testing electrostatic lightning laboratory, professional recommendation of the most suitable components to solve electromagnetic compatibility problems.