The power input of the gateway device should support single-phase AC 220 V input, and the power output end, according to the classification of the gateway, should meet the following requirements:
a) Class I: At least one DC output should be supported.
b) Category 2: At least one DC 12 V (max. 2 A) output and at least one dc 24 V (max. 2 A) output should be supported, and one dc 48 V (max. 2 A) output should be supported. It should have voltage, current, power and energy consumption detection functions;
c) Category 3: At least two DC 12 V (max. 2 A) outputs and at least two DC 24 V (max. 2 A) outputs should be supported, and one DC 48 V (max. 2 A) output should be supported. It should have voltage, current, power, energy consumption detection and overvoltage, undervoltage, overload and other power protection functions;
d) Category 4: At least two DC 12 V (max. 2 A) outputs and at least two DC 24 V (max. 2 A) outputs should be supported, and one DC 48 V (max. 2 A) output should be supported. PoE power delivery supporting IEEE802.3 af/at/bt international standards. It should have voltage, current, power, energy consumption detection and overvoltage, undervoltage, overload and other power protection functions;
e) If necessary, the gateway device may support controllable AC output.
Shanghai Leiditech recommends AC220V AC power surge protection scheme
Scheme advantages: used to meet the surge protection of 220V AC power interface, choose different levels of protection devices according to the environment of the power supply, and meet the IEC61000‐4‐5 4KV~8KV different levels of testing.
Recommended model of Shanghai Lei Wei: MOV 14D471K (varistor voltage 470V, bidirectional)
GDT 2R600-8L (800V, bidirectional, 8/20 surge 10KA)
Shanghai Leiditech recommends 12V DC power surge protection scheme
Scheme advantages: used to meet the surge protection of 12V DC power interface, select the TVS device with appropriate protection current according to the environment where the power supply is located, meet IEC61000‐4‐2, level 4, contact discharge 8KV, air discharge 15KV. To meet the IEC61000‐4‐5 surge high-level test, high-power SMC devices are required.
Recommended model:SMBJ15CA (15V, 600W, bidirectional, SMB package)
SMCJ15CA (15V, 1500W, Bidirectional, SMC Package)
SMDJ15CA (15V, 3000W, Bidirectional, SMC Package)
interface, select the appropriate TVS device with the appropriate protection current Scheme advantages: used to meet the surge protection of 24V DC power according to the environment where the power supply is located, meet IEC61000-4-2, level 4, contact discharge 8KV, air discharge 15KV. To meet the IEC61000-4-5 surge high-level test, high-power SMC devices are selected.
Recommended model:
SMBJ26CA (26V, 600W, bidirectional, SMB package)
SMCJ26CA (26V, 1500W, bidirectional, SMB package)
SMDJ26CA (26V, 3000W, bidirectional, SMC package)
Shanghai Leiditech recommends 48V DC power surge protection scheme
Scheme advantages: used to meet the surge protection of 48V DC power interface, according to the environment of the power supply to select the appropriate protection current TVS device, to meet IEC61000‐4‐2, level 4, contact discharge 8KV, air discharge 15KV. To meet the IEC61000‐4‐5 surge high-level test, high-power SMC devices are required.
Recommended model:
SMBJ54CA (54V, 600W, bidirectional, SMB package)
SMCJ58CA (58V, 1500W, Bidirectional, SMC Package)
SMDJ58CA (58V, 3000W, Bidirectional, SMC Package)
The above are commonly used design schemes, if there are special needs, welcome to discuss together, the product is fine.
Leave a Reply
- EMC Protection Device Selection for a Driver-Monitoring Camera
- Encoder Interface ESD Protection
- Personnel detection system interface protection design and component selection
- EMC Protection for Gas Detection Systems: Four Entry Points from Power to Wireless
- PoE power supply methods and EMC protection in the DC power supply system of intelligent logistics r